Frequently asked questions about bolted joint calculation
What is VDI 2230?
It is the guideline of the Association of German Engineers (VDI) for the systematic calculation of highly stressed bolted joints. Part 1 covers joints with one cylindrical bolt and Part 2 multi-bolted joints.
Which checks does Bolty perform?
Steps R0 to R13 of Part 1: required clamp load, load division, preload losses, assembly preload, working stress, fatigue, surface pressure, thread engagement, slipping, shearing and tightening torque.
Can I calculate a flange or a bolt array?
Yes. You enter the pattern (circular flange, rectangular or free coordinates) and the total loads, and Bolty distributes forces and moments between the bolts as a rigid body, following Part 2.
What is out of scope?
Reduced-shank or fitted bolts, thin nuts, opening joints, loss of strength at high temperature and the elastic or finite element models of Part 2. For those cases you can ask us for the calculation.
Does it replace the responsible engineer?
No. Bolty automates the procedure and documents the steps, but validating the assumptions, the input data and the results is up to the engineer responsible for the design.